Building with Metal: Inside fire and earthquake testing
November 26, 2026 at 7:00 a.m.By The Coffee Shops®.
Bob Zabcik explains how engineers use full-scale fire, seismic and multi-hazard testing to create safer, more resilient buildings.
In episode 69 of Building With Metal (sponsored by McElroy Metal), host Kathi Miller hosts Bob Zabcik, member and owner of Z-Tech Consulting, for a conversation about the science behind fire and earthquake testing. Bob opened the conversation by talking about UC San Diego’s full-scale building test. This test saw the construction of a 10-story cold-formed steel building (standing 103 feet tall). The building was built on the UC San Diego shake table. The National Science Foundation rebuilt the table in 2022 for $16.3 million, giving it six degrees of freedom. In addition to moving in three directions, the table can rotate and twist.
The researchers ran a modified version of the 1989 Loma Prieta earthquake through the structure. Commonly known as the World Series earthquake, the magnitude 6.9 event was scaled up for the test to represent a one-in-2,500-year occurrence, which the building code identifies as a maximum considered earthquake. This is not the first time researchers have built full-scale structures to test, but it was the first test of this size (most tests are limited to 6-story buildings). Members of the Steel Framing Industry Association funded the materials.
After the shaking stopped, researchers placed wood pallets inside the structure and set the building on fire. Why set it on fire? To the structure’s passive fire protection. What is passive fire protection? Basically, the fire protection systems we think of, like sprinklers and extinguishers, are active protection. They respond when the fire occurs. As for passive, that protection comes from the building itself. Rather than requiring activation, these systems are designed to resist the spread of heat, flames and smoke.
The reason researchers lit the building on fire after shaking it is because passive fire protection becomes far more important after earthquakes. Bob explained, “Just as gas lines can rupture, the water line could rupture too. There’s no [guarantee of] active fire protection available right after the [quake] event. All you’ve got is passive protection at that point.”
Typically, passive fire assemblies are tested in pristine condition. They are constructed in a furnace, exposed to a standardized fire and assigned a rating. Very few systems are tested after earthquake movement has loosened joints or displaced fasteners. This test helped investigate that gap. And what researchers found was that the system generally performed well, but flames and smoke traveled through some of the joints that had loosened during the simulated earthquake. Researchers measured the cracks and joints as the building was dismantled, creating data that can inform future testing.
This is just one example of how building science is helping us build a stronger, safer built environment. As Bob put it, “I’m almost going to accept the fact that the building is going to fail or at least that it won’t be usable when it’s done. That’s not really the goal. The goal is to keep the building standing and stable, so the occupants have time to get out [and research like this test is key to finding out how to do that].”
Learn more about Metal Construction Association (MCA) in their Coffee Shop Directory or visit www.metalconstruction.org.


















Comments
Leave a Reply
Have an account? Login to leave a comment!